Multifunctional and modular safety systems

Apart from a variety of classic monofunctional safety modules, such as emergency stop modules, DOLD also offers multifunctional safety modules and systems. For this, DOLD integrates more and more functionality in less space.



In the compact multifunctional SAFEMASTER®C safety module several safety-related inputs are assigned to a single output. The selection of available safety functions includes:
• Emergency stop
• Safety gate
• Electro-sensitive protective equipment (ESPE), e.g. light barriers
• Two-hand safety button type IIIA or IIIC acc. to EN 574
• Functions and operating modes can be easily selected by rotary switches.

With SAFEMASTER®M as a modular safety system it is possible to tailor the safety functions to the relevant application in a cost-saving manner. Evaluation includes:
• Emergency stop
• Safety gate
• Electro-sensitive protective equipment (ESPE), e.g. light barriers
• Two-hand safety button type IIIA or IIIC acc. to EN 574

Input modules with freely selectable safety functions can be assigned to different output modules. An optional field bus connection allows system status visualization. 
Safemaster C:
• Save cost by multifunctionality
• Save space in the switch cabinet compared with monofunctional safety modules
• Reduces stockkeepingEasy and quick setting of safety functions and operating modes
Safemaster M:
• Save cost thanks to multifunctionality, modular design and status signalling
• Save space in the switch cabinet by optimized system tailoring to the application
• Reduces stockkeeping
• Device configuration without software
• Versatile
• Hierarchic grouping by incorporation of locally acting safety functions in overriding emergency-stop circuits
• Increase system availability by visualization
• Reduce downtimes by quick diagnosis of the cutoff cause
• Quick module mounting thanks to detachable terminals and plug-type connections
• Flexible use with monitoring of a variety of safety sensors

Multifunctional safety module: SAFEMASTER®C
FunctionApplicationCategory acc.
to EN 954
Type
EN 574
Safe output
contacts
ApplicationWitdh
[mm]
Type
Emergency- stopLicht- gitterSchutz- türZwei- handStartStoppWire- lessNC contactRückführung f. ext. Überwachg.
Multifunctional
safety module
+++++4IIIA/IIIC31+45BH 5910
For more complex applications see SAFEMASTER®M
Multifunctional safety solutions: SAFEMASTER®M
FunctionApplicationCategory
EN 954
Type
EN 574
Safe output contactsAuxiliaryWidth [mm]Type
Emergency- stopsLicht- gitterSchutz- türZwei- handStartStoppWire- lessRedundant NO contacts Zeitver- zögerungHalb- leiterHalbleiter zeitverzögertNC contactRückführung f. ext. Überwachg.
Control Unit++4143+45BH 5911.03
Control Unit++41421+45BH 5911.22
Input module++++4 IIIA/IIIC22.5BG 5913.08/_0_ _ _
Input module with
isolated inputs
++++4 IIIA/IIIC45BH 5913.08/_0_ _ _
Input module++++4 IIIC22.5BG 5913.08/_1_ _ _
Input module++++4IIIC22.5BG 5913.08/_2_ _ _
Input module+++4IIIC22.5BG 5913.08/_3_ _ _
Input module++422.5BG 5914.08/_0_ _ _
Input module with
isolated inputs
++445BH 5914.08/_0_ _ _
Input module with
monitoring function
++422.5BG 5915.08/_1_ _ _
Input module with
monitoring function
and isolated inputs
++445BH 5915.08/_1_ _ _
Input module with
wireless safety
+++++445BG 5915.04
Output module4+22.5BG 5912.04
Output module31+22.5BG 5912.48
Output module3+22.5BG 5912.86
Output module21+22.5BG 5912.95
Output module with
semiconductor outputs
2+22.5BG 5912.88
Output module with
semiconductor outputs
22+22.5BG 5912.89
Diagnostic Module
for CANopen
22.5BG 5551
Diagnostic Module
for Profibus DP
45BH 5552