Home » Data recorders » PHС series
Fuji Electric, Data recorders PHС series
The microjet recorder is a revolutionary recorder, its ink jet color printer technology is adopted in industrial type recorders for the first time in the world. Fuji established ink jet technology based on the unique silicon chip manufacturing process for FCX transmitters. The ink jet printing mechanism provides up to 24 continuous traces with a 180mm width recorder and 6 continuous trace with a 100mm width recorder without pen offset. The mechanism also provides six sharply defined colors. Microjet recorder was designed with a reduced number of complicated mechanical parts to make it as trouble-free as possible.
The ink jet head is formed on a stable quality silicon chip. The ink jet head printing mechanism does not touch the chart paper, allowing reliable recording.

The ink jet mechanism is formed on a thin silicon chip (17.6 x 16mm) using silicon micro machining technology. It is provided with piezo elements. With voltage applied to the piezo elements, the shape of the elements changes as shown in the diagram, and ink particles are ejected from the tip of the nozzle. These particles are very small and fast, and draw a series of very small dots of about 0.3mm diameter on the chart paper. These small dots are combined together to form characters and trace lines for clear visible recording.

Самописец

This recorder can record a maximum of 6 channels of DC voltage, mA, thermocouples and resistance bulbs. The adoption of an ink jet system makes it possible to record measured data in analog trace mode or to print in digital mode at a high speed. This 100 mm-wide recorder performs recording clearly in 6 different colors.

Specification:

Model

PHC

Chart width/length

100mm/15m

No. of input channel

1/2/3/6

Input Signal type

TC (J, K, E, R, B, S, T, L, U, W, PN, N), RTD, DC V (±50mV,±500mV, ±5V, ±50V DC), DC mA

Measuring cycle

160/320ms.

Accuracy

Display Accuracy: ±0.15% of measuring range, ± 1 digit without cold junction compensation error

Analog Trace Accuracy: display accuracy ±0.25% of measuring range

Display

Fluorescent (20 characters x 2 lines)

Chart speed

5-400mm/h continuous trace
401-1500mm/h intermittent trace

Recording cycle

= 400/chart speed (more than 2 seconds)

Calculation

Square root extraction, Subtraction, Scaling, Input filter, Logarithm

Report Generation

Daily report, Totalize list, Parameter list, Test pattern, Measured value list, Logging print, Message print

Alarm

H, L, RH, RL for each input, Burnout, Ink-out, Chart end, Battery alarm

Option

Alarm output: 6 Relay output
Remote control: Record start/stop, Chart speed change, Measured value print, Message print
Communication: RS-485
Chart Illumination: Cold cathode fluorescent

Power supply

100-120V AC or 200-240V AC
(Usable Range 85-150VAC or 150-300VAC)

Environmental

Temperature: 0 to 50°C IEC IP50
Humidity: 20 to 80%RH
(Temp. (°C) x Humi. (%RH) < 3200)

Mass {weight} Approx.

2.1kg (without options)